Diameter of a steel ball is measured using a Vernier calipers which has divisions of 0.1 cm on its main scale (MS) and 10 divisions of its Vernier scale (VS) match 9 divisions on the main scale. Three such measurements for a ball are given as:
S.No. MS (cm) VS divisions

  1. 0.5 8
  2. 0.5 4
  3. 0.5 6

If the zero error is - 0.03 cm, then mean corrected diameter is:

  1. (1)

    0.53 cm

  2. (2)

    0.56 cm

  3. (3)

    0.59 cm

  4. (4)

    0.52 cm

Show answer

Option (3) is correct.

Key from source paper